User Tools

Site Tools


how_to:includeumcinamtdb

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
how_to:includeumcinamtdb [2010/07/28 09:31]
132.168.74.230
how_to:includeumcinamtdb [2010/08/02 16:57] (current)
132.168.74.230
Line 11: Line 11:
  
  
-  - Check if the ePims web server ​URL is correct+  - Add ePims Web Server ​URL
       * The ePims WebService is used to extract Sample information from Run name       * The ePims WebService is used to extract Sample information from Run name
 +  - Option: Continue processing on ePims WebService error 
 +      * If sample name is not retrieved from ePims WebService for any reasons (connection failed, ...) and if you checked this option, the tool will continue to process the current run and leave the sample name blank. If not checked, the run will be skipped and the tool will continue with next one.
   - Select one or several UMC directories   - Select one or several UMC directories
       * A valid UMC directory is named **//<​RunName>//​_isos** ​       * A valid UMC directory is named **//<​RunName>//​_isos** ​
Line 18: Line 20:
   - Select the AMT database (MS Access format) to populate with UMCs   - Select the AMT database (MS Access format) to populate with UMCs
       * See here to know how to [[how_to:​generateamtdb|create an AMT database]]       * See here to know how to [[how_to:​generateamtdb|create an AMT database]]
-      * A backup copy of your AMT database is created before processing (stored in the same location as you AMT database). :!: If a backup copy already exists, this one is overwritten by the new one without any prompting. If the backup copy fails (not enough permissions,​ ...), you are encouraged to cancel the process, make the backup copy yourself and recall the tool.  +      * A backup copy of your AMT database is created before processing (stored in the same location as you AMT database). ​ 
-  - Indicate if the matching is larged ​or not +      * :!: If a backup copy already exists, this one is overwritten by the new one without any prompting. ​ 
 +      * If the backup copy fails (not enough permissions,​ ...), you are encouraged to cancel the process, make the backup copy yourself and recall the tool.  
 +  - Indicate if the UMC matching is larged ​(without filtering) ​
       ​       ​
-When processed is finished, a dialog message indicates ​the number of successfull ​runs. If the process encountered problems with some runs, look at the log file to know the concerned runs. {{ :​how_to:​readumcsmesssuccess.png |}}+       
 + 
 +==== End message ==== 
 +       
 +When processed is finished, a dialog message indicates ​if all processed runs were successfull ​or not.\\ 
 +If the process encountered problems with some runs, you will find more details in the log file. 
 + 
 +==== Classic error ====
  
-  
 {{ :​how_to:​readumcsclassicerror.png|}} :!: You may encounter this error when running tool. This kind of error often occurs when the AMT database has been opened with MS Access. Even if you only browse some records in table and quit without saving, the database may be affected (the size of your .mdb file is increased!).  ​ {{ :​how_to:​readumcsclassicerror.png|}} :!: You may encounter this error when running tool. This kind of error often occurs when the AMT database has been opened with MS Access. Even if you only browse some records in table and quit without saving, the database may be affected (the size of your .mdb file is increased!).  ​
  
Line 31: Line 41:
 ===== View results ===== ===== View results =====
  
 +Open you AMT database in MS Access, if everything worked fine, the following tables are filled in with new data:
 +  * Run
 +  * UMC
 +  * Match_UMC_AMT
  
 +:!: Think about compacting your AMTdb if you intend to continue populating your AMTdb with UMCs from other run(s).
how_to/includeumcinamtdb.1280302287.txt.gz · Last modified: 2010/07/28 09:31 by 132.168.74.230